Craftsman SSI65 Stud Finder Owner's Manual

Craftsman Laser Tools Owner's Manual - SSI65 Stud Finder.
Download
Page  of 1
4.7, 2095 votes
background image

Electrical field locators may not detect 

live AC wires if moisture is present 

in the wall, or if wires are more than 51 mm from the 

scanned surface, in plastic conduit or behind a plywood 

shear wall or metallic wall covering. Do not rely exclusively 

on the detector to locate items behind the scanned surface. 

Use other information sources to help locate items before 

penetrating the surface. Such additional sources include 

construction plans, visible points of entry of pipes and 

wiring into walls, such as in a basement, and in standard 

16” and 24” stud spacing practices.

DO NOT ASSUME THERE ARE NO  

LIVE ELECTRICAL WIRES IN THE 

WALL. DO NOT TAKE ACTIONS THAT COULD BE 

DANGEROUS IF THE WALL CONTAINS A LIVE  

ELECTRICAL WIRE. ALWAYS TURN OFF THE ELECTRICAL 

POWER, GAS, AND WATER SUPPLIES BEFORE 

PENETRATING A SURFACE. FAILURE TO FOLLOW THESE 

INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, 

AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.

8. OPERATING CAUTIONS
Depending on the proximity of electrical wiring or pipes to 

the wall surface, the scanner may detect them in the same 

manner as studs. Caution should always be used when 

nailing, cutting, or drilling in walls, floors, and ceilings that 

may contain these items.
To avoid surprises, remember that studs or joists are 

normally spaced 16 in. (406 mm) or 24 in. (610 mm) 

apart and are 112 in. (38 mm) in width. Anything closer 

together or a different width may not be a stud, 

joist, or firebreak. Always turn off the power when 

working near electrical wires.

9. SCANNING DIFFERENT SURFACES
Freshly painted walls:
 Must dry a minimum of one week 

after application.
Wallpaper: Stud finder functions 

normally on walls covered with 

wallpaper or fabric, unless the 

materials are metallic foil, contain 

metallic fibers, or are still wet  

after application. Wallpaper may 

need to dry for several weeks 

after application.
Textured walls or acoustic 

ceilings: When scanning a ceiling 

or wal  with an uneven surface, 

place thin cardboard on the surface 

to be scanned and scan over the 

cardboard. Calibrate with cardboard 

in place.
Wood flooring, subflooring, 

or gypsum drywall over 

plywood sheathing: Use the High 

Sensitivity mode and move the tool slowly. The Signal 

Strength Indicator may only display 1 or 2 bars when the 

tool locates a stud through thick surfaces.

5. DIFFICULTY LOCATING A STUD? 
    TRY HIGH SENSITIVITY MODE
If you have difficulty locating a stud after 

following Step 4, it could be that the stud 

is deep or the walls are thick. With the unit 

still placed flat against the wall and turned 

on, quickly (within one second) release and 

re-press the Power button. The Stud Scan 

mode indication will flash continuously, 

indicating that the tool has entered High 

Sensitivity mode. The center of a very deep 

stud will be 

indicated by the 

four middle bars 

illuminating.

6. MARKING THE CENTER 
  OF THE STUD
Once an object is located, mark the location 

where the SpotLite

® Pointing System 

illuminates. This is the center of the stud.

4. FINDING A STUD
Always start with the scanner placed flat against the wall, 

then press the Power button. Wait for beep to confirm 

calibration has completed before moving tool.

Slowly slide tool 

across surface. EDGE 

display will illuminate, 

indicating location of 

the stud edge.

Continue sliding tool. 

When the center of 

stud is located with 

three bars on the Signal 

Strength Indicator, 

the buzzer will sound, 

and the four middle 

bars, CENTER display, 

and SpotLite

® Pointing 

System will illuminate.

In cases of deeper studs 

(or thicker walls) when 

the center of the stud is 

located, only two bars 

will show on the Signal 

Strength Indicator and 

only the SpotLite

® beam 

and four middle bars will 

illuminate. If you still can’t 

locate a stud, try the next step.

The tool may detect other objects 

behind the wall such as pipes and 

conduit. See Section 8: Operating Cautions for ways to 

confirm that you found a stud.  

7. WIREWARNING® DETECTION
The WireWarning

® detection works continuously. When 

live AC voltage is detected, the WireWarning

® detection 

indicator will appear in the display.
If scanning begins over a live AC wire, the WireWarning

® 

detection indicator will flash continuously.

Craftsman®

Stud Finder

This Craftsman® stud finder detects both the 

center and edges of wood and metal studs and 

joists in walls, floors, and ceilings in one step. 

It features a durable high-impact case and the 

patented SpotLite® Pointing System. It also has 

WireWarning® detection to continually detect 

hot AC voltage when scanning for studs.

1. INSTALLING THE BATTERY
Press battery door release in with your finger or a coin 

and lift up to remove door. 
Place 9-volt battery into the compartment and press 

into place.
Replace battery door and snap shut.

2. OPERATING TIPS
For optimum scanning results, it is important to properly 

hold the stud finder and move slowly when scanning. The 

following tips will provide more accurate scanning results:
•Graspthehandlewithyourthumbononesideand 

your fingers on the other side. Make sure your fingertips 

are resting on or above the running board and not 

touching the surface being scanned or the scanning 

head of the tool.

•Holdthetool

straight up and 

down, parallel to 

the studs, and do 

not rotate the tool.

SpotLite

® 

Pointing System

Signal Strength 

Indicator

LCD Display

Battery 

(back of unit)

Edge or Center 

Indication

Auto Correcting 

Indication

WireWarning

® 

Detection Indication

Stud Scan Mode 

Indication

Running Board

Power Button

•Keepthetoolflatagainstthewallanddonotrockor

tilt the tool when slowly sliding across the surface 

being scanned.

•Avoidplacingyourotherhand,oranyotherpartofyour

body, on the surface being scanned. This will interfere 

with the tool’s performance.

3. TURNING ON/CALIBRATING THE TOOL
•Placestudfinderflatagainstthewall,thenpressand

hold the Power button. The LCD will display all icons 

until calibration is complete. Upon completion of 

calibration, the SpotLite

® Pointing System and buzzer 

will momentarily activate and the tool will begin 

continuous measurements.

Note: It is important to wait for calibration to complete 

(1–2 seconds) before moving the scanner. 
•ACT™(Auto Correcting Technology) — The tool will 

automatically recalibrate itself when needed during 

scanning. This recalibration is usually transparent and 

no indication is made. If an arrow icon illuminates, the 

tool was calibrated near or over a stud and then moved 

away. The arrow indicates the direction of the 

missed stud.

FCC Part 15 Class B Registration Warning
This device complies with Part 15 of FCC Rules.  Operation is subject to the following two conditions: (1) this device may not cause harmful interference, 

and (2) this device must accept any interference received, including interference that may cause undesired operation.

ACT,CenterVision,SpotLite,andWireWarningareregisteredtrademarksortrademarksofZirconCorporation.•P/N63030•RevB06/11

10. HELPFUL HINTS

WARNING

CAUTION

WARNING

All LCD segments 

turn on at the 

same time and 

the unit beeps 

continuously.

Detects other 

objects besides 

studs. 

You suspect 

electrical wires, 

but do not  

detect any. 

Area of voltage 

detection is  

too large.

•Unitnotflatagainstwall.
•Unittiltedorliftedduringscan.(Allthese

factors affect proper calibration.)

•Scanningsurfaceistoodenseortoowet 

for unit to operate.

•Electricalwiringandmetalorplasticpipes

may be near or touching back surface of wall.

•Wiresareshieldedbymetalconduit,abraided

wire layer, behind metallic wall coverings, 

plywood shear wall, or other dense material.

•Wiresmaynotbelive.
•Wiresdeeperthan2in.(51mm)from

surface might not be detected.

•Voltagedetectioncanspreadondrywallas

much as 12 in. (305 mm) from each side of 

an actual electrical wire.

•Onroughsurfaces,placepieceofpaperonwall,scanningthroughittohelpslideunitmoresmoothly.
•Keephandatleast6in.(152mm)fromthestudfinderwhileyoucalibrateandscan.Holdunitwith

thumb and index finger no higher than handgrips. Be careful not to move your fingers after calibration.

•Alwaysholdunitparalleltoandmoveperpendiculartoobjectyou’retryingtolocate.
•Ifyouareusingunitonarecentlytaped,painted,orwallpaperedwall,allowtimetodryandtryagain.
•Whileunitisstillon,quicklyreleaseandre-pressthePowerbuttontoenterHighSensitivitymode.

•Checkforotherstudsequal yspacedtoeitherside12,16,or24in.(305,406mm,or610mm)apart,

or check for the same stud at several places directly above or below the first finding. Studs wil  run 

straight up and down from floor to ceiling, while pipes may change direction.

•Seeabovesolution.
•Useextracautioniftheareahasplywood,thickwoodbackingbehinddrywal , 

or thicker-than-normal walls. 

•Ifaswitchcontrolsanoutlet,makesureitisONfordetection,butturnedoffwhenworking 

near electrical wires.

Always turn off the power when working near electrical wires.

•Tonarrowdetection,turnunitoffandonagainattheedgeofwherewirewasdetected 

and scan again.

Probable Cause

Solution

Situation

Lath & Plaster: Due to irregularities in plaster thickness, this tool is not recommended for use on lath & plaster.
Stud finder cannot scan for wood studs and joists through carpeting and pad. In Stud Scan mode, the stud finder will 

NOT be able to scan through dense materials such as glass, ceramic tile, and foil.
Note: Sensing depth and accuracy can vary due to moisture content of materials, humidity, wall texture, and paint.

0.679769s