Reviewing Programs:
1.  To review the programs that have been entered, press and release the “PROG” key. 

Each time you do this you will be able to scroll thru the programs.

2.  Any program can be edited by pressing the “HOUR”, “MIN”, and “DAY” keys. Then 

press the “PROG” key in order to accept the changes.

3.  When complete press the “CLOCK” key to return to current time and day.

Deleting Programs:
1.  To delete a particular program simply press the “PROG” key until the desired 

program is displayed.

2.  Then press the “HOUR” and “MIN” keys until --:-- is displayed. Then press the 

“PROG” key in order to delete this particular program. 

3.  When complete press the “CLOCK” key to return to current time and day.

Electrical Ratings:
120VAC 60Hz
15A Resistive
15A Tungsten
1HP

*When done programming,            
  close door.

Manual Override:
Pressing the door will override the timer 
setting and will manually turn the switch 
ON and OFF.

Initial Startup:
When you initially program the unit it 
may be necessary to press the manual 
override key as the unit will not look 
back to determine if it should be ON. For 
example if the current time is 2:00PM 
and you just programmed the unit to 
turn ON at 1:00PM, you will need to 
press the manual override key to turn 
it ON. Thereafter, the unit will resume 
normal operation (automatic).

MEMORY BACKUP:
This timer is equipped with a 
rechargeable Ni-Mh battery which will 
protect your programs during power 
failure for up to 30 days. 
No need to replace battery.

Note that the screen blanks if the battery 
is discharged completely.
 

 is a trademark of the General Electric Company and is used under license to Jasco 

Products Company LLC, 10 E. Memorial Road, Oklahoma City, OK 73114.
This Jasco product comes with a 1 year limited warranty.  
Visit www.jascoproducts.com for details.

Smart Digital Timer

Installation Instruction
1.  Turn OFF the main power.
2.  Remove the existing switch.
3.  Connect the wires of Timer and wall box as followed by using the wire nuts provided. 

a) Connect the Hot/Live wire of main power to the Black wire from Timer. 
b) Connect both the Neutral wires of main power and Load to the White wire from Timer. 
c) Connect the Hot/Live wire of Load to the Red wire from Timer. 
d) Connect the Ground wire to the Green wire from Timer. 
 
Note: Be sure that all wire nuts are secure.

4.  Tuck the wires into the wall box leaving room for the Timer. Using the screws provided. 

Mount the timer to the wall box being careful not to crush any wires. 

5. Turn Main power ON

POWER-UP SEQUENCE:
1.  Lift up the bottom of the door using a small slotted screwdriver.
2.  Position the slide switch to TIMER.
3.  Press the “RESET” button using a paper clip.
4.  The display should flash 12:00AM on Monday.

Setting Current Time:
1.  Press and HOLD the “CLOCK” key during this entire procedure.
2.  Press the “HOUR” key to advance the hours.
3.  Press the “MIN” key to advance the minutes.
4.  Press the “DAY” key to advance the day.
5.  If any keys are pressed for a prolonged period, the display will  

advance rapidly.

6.  Release the “CLOCK” key once the time and day have been entered. Now the timer is in 

operation and ready to be programmed. The colon “:” after the hours will continuously 
flash indicating that the clock is running.

Programming ON/OFF Events:
1.  Press the “PROG” key once. TIMER 1 on - - : - - appears.
2.  Using the “HOUR” and “MIN” keys enter the desired ON time. By default all days are 

indicated. See block programming below for selecting different days.  When complete press 
the “PROG” key once. 

3.  Timer OFF --:-- will be displayed. Using the “HOUR” and “MIN” keys enter the desired OFF 

time. By default all days are indicated. See block programming below for selecting different 
days. When complete press the “PROG” key once.

4.  If complete press the “CLOCK” key to return to current time  

and day.

5.  Note that a total of 7-ON and 7-OFF events can be programmed.

Block Programming:
1.  When programming ON/OFF events, all days are indicated by default. To change the day 

selection simply keep pressing the Day key and the display will change as follows:

2.  Individual Day (MON, TUE, etc.)
3.  MON~FRI; SAT~SUN; MON~SAT; MON~SUN
4.  MON~WED~FRI; TUE~THU~SAT
5.  MON~WED; THU~SAT
6.  Follow the steps above to complete programming. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

120VAC Hot

Neutral

BLACK

WHITE

RED

Ground 
(GREEN)

Lights/Fans/etc.