GE JTP30DPBB User's Manual

GE Ovens User's Manual - JTP30DPBB.
Download
Page  of 3
4.2, 1894 votes
background image

Dimensions and Instal ation Information (in inches) 

For answers to your Monogram,® GE Profile™ or  

GE® appliance questions, visit our website at 

ge.com or call GE Answer Center® service,  

800.626.2000.

320228

Specification Created 5/09

JTP30DP 
GE® 30" Built-In Single Wall Oven

 

Listed by 

Underwriters 

Laboratories

KW Rating

240V

4.5

208V

3.4

Breaker Size

240V

20 Amps

208V

20 Amps

Most 30" Wall Cabinets can be used with this unit.
Note:
 These ovens are not approved for stackable 

installations.
Note: Cabinets instal ed adjacent to wal  ovens 

must have an adhesion spec of at least a 194°F 

temperature rating.
Door handle protrudes 3" from door face. Cabinets 

and drawers on adjacent 45° and 90° walls should be 

placed to avoid interference with the handle.
Installation Information: Before installing, consult 

instal ation instructions packed with product for 

current dimensional data.
Electric wal  ovens are not approved for instal ation 

with a plug and receptacle. They must be hard 

wired in accordance with installation instructions.
Side-by-side installations require at least 2" 

between cutouts.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit 

48-1/2" 

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

0.528307s