Dimensions and Installation Information (in inches)

For answers to your Monogram,® GE Profile™ or  
GE® appliance questions, visit our website at 
ge.com or cal  GE Answer Center® service, 
800.626.2000.

PP932TM/KM/BM
GE Profile™ 30" Built-In CleanDesign Electric Cooktop

 

220585

Listed by 

Underwriters 

Laboratories

Note: Check local codes for required breaker size

Important: Requires a 5" free area between the 
bottom of the cooktop to any combustible material, 
i.e., shelving. Free area not required when instal ing 
wal  oven underneath cooktop. Refer to instal ation 
instructions. Requires a 15" minimum from cooktop to 
adjacent overhead cabinets. Units are furnished with a 
48" flexible armored cable. 

Note: 30" Ribbon cooktops are approved for use over select GE 27" and GE 30" 
Single Wal  Ovens and Warming Drawers. Refer to cooktop and wal  oven/ 
warming drawer instal ation instructions packed with product for current  
dimensional data. If instal ed with a GE Profile™ Telescopic Downdraft System, 
consult both the cooktop and downdraft instal ation instructions packed with 
product before instal ing. Cooktop gas/electric supply may need to be re-routed 
to instal  downdraft. Consult cabinet and countertop manufacturer’s specs for 
flush mount instal ation prior to instal . 

Before instal ing, consult instal ation 

instructions packed with product for current dimensional data. 
Fil er Trim Kit: When replacing an old GE 30" cooktop (with larger opening)  
use the fol owing one-piece trim kit to fil  in the over-size hole. Available at  
additional cost. JXTR32W (True White) JXTR32B (Black glass) JXTR32C  
(True Bisque)

KW Rating

240V

8.6

208V 6.5

Breaker Size

240V

40 Amps†

208V 40 Amps†

3-1/4*

Cooktop

2-1/2**

Required

28-1/2

19-5/8

29-3/4

30_color_cktp_instal .eps

21-3/8

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

1-1/2" MIN.

clearance to

side wal

from cut-out

1-1/2" MIN.

clearance to

side wal

from cut-out

1-3/4" to

rear wal

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/2" on models PP980/975/950/945 and 4-5/8" 

on models PHP900/PP972/962/942/932/912, 

JP655/356/346.

 **Raised bul  nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

Specification Revised 12/07