Dimensions and Instal ation Information (in inches)

Instal ation Flexibility 
These ovens may be instal ed in combination with a Monogram 
warming drawer. 

Note: Cabinets instal ed adjacent to wal  ovens must have an  
adhesion spec of at least a 194°F temperature rating.

Instal ation Information: Before instal ing, consult instal ation  
instructions packed with product for current dimensional data.

For answers to your Monogram,® GE Profile™ or  

GE® appliance questions, visit our website at 

ge.com or cal  GE Answer Center® service,  

800.626.2000.

Specification Revised 5/07

130186

ZET958SM/BM/WM 
GE Monogram® 30” Built-In Double Oven

 

KW Rating
240V

8.0

208V

6.0

Breaker Size
240V

40 Amps

208V

40 Amps

Listed by 

Underwriters 

Laboratories

28-1/2" Min.

        28-5/8" Max.

51-13/16"

Min.

51-15/16"

Max.

12"

Locate Junction Box 47"

Above Cutout Floor, Within 5"

of Right Rear Wall

30"

52-7/8"

23-1/4"

Recessed

Depth

29-3/4"

23-1/2"

Min.

28-1/2" Min.

        28-5/8" Max.

51-13/16"

Min.

51-15/16"

Max.

12"

Locate Junction Box 47"

Above Cutout Floor, Within 5"

of Right Rear Wall

30"

52-7/8"

23-1/4"

Recessed

Depth

29-3/4"

23-1/2"

Min.

The solid bottom or runners must be level with the bottom of the 
cutout, or the bottom trim may not instal  correctly and could 
interfere with the door opening. If the cabinet does not have a 
solid bottom, two braces or runners must be instal ed level with 
the bottom of the cutout to support the weight of the oven. The 
runners and braces must support 300 lbs. (135 kg).

NOTE: Install the

oven only with

specific models

listed on the label

located on top of

the oven.

Anti-Tip Block

Against Rear

Wall Per

Warming

Drawer

Requirement

2   (5.1 cm)

Min.

1   (2.5 cm) Min. Above Toekick

Per Warming

Drawer

Requirement