Honeywell RTH111 series Owner's Manual

Honeywell Thermostats Owner's Manual - RTH111 series.
Download
Page  of 8
4.6, 1097 votes
background image

RTH111

      69-2061EFS

-01                    11/09                    1/8

1.1

Controls

1.2

Display screen

1.3

System switch

Use the System switch to place the system in one of the following
modes.
• Cool: System is in Cooling mode.
• Off: System is off.
• Heat: System is in Heating mode.

CAUTION: EQUIPMENT DAMAGE HAZARD
Do not use Cooling mode when the outdoor temperature
is below 50 °F (10 °C).

1.4

Fan switch

Use the Fan switch to select the fan operation.

• Auto: The fan runs only when heating or cooling is actually taking

place (commonly used setting).

• On: The fan runs continuously. Use this setting for improved air

circulation or for more efficient air cleaning.

1.5

Temperature adjustment

Press the S or T button once to display the setpoint temperature. 
Press either button more than once to change the setpoint.
The ambient (measured) temperature is normally displayed. To view
the setpoint temperature, press either of the temperature adjustment
buttons once. The setpoint temperature will appear for five seconds.

1.6

Built-in compressor protection

Your thermostat has a feature that helps prevent damage to the
compressor of your air conditioning system. Because damage can
occur if the compressor is restarted too soon after shutdown, this
feature forces the compressor to wait five minutes before restarting.
During the wait time, the message Cool On flashes on the screen.
When the safe wait time has elapsed, the message stops flashing
and the compressor turns on.

Set the System switch to Off before removing the
batteries. Otherwise, the heating/cooling system could
remain activated even when batteries are removed.

Install two fresh AAA batteries when the low-battery icon flashes on
the screen. The icon appears for 60 days before the batteries are
depleted. Replace batteries once a year, or when you will be away for
more than a month.
The settings are stored in non-volatile (permanent) memory and are
thus saved when the thermostat is without batteries.

Operation

1.

System switch

Fan switch

Temperature 

adjustment buttons

1 When Cool On is flashing, this means the compressor protection is engaged (see

section 1.6).

Temperature

System status

• Cool On: Cooling is 
activated. 1

• Heat On: Heating is 

activated.

Low-battery warning

Setpoint indicator

Appears when the 

setpoint temperature 

is displayed.

Battery replacement

2.

In case of difficulty

3.

Screen is blank.

• Ensure two fresh AAA alkaline batteries are 

correctly installed.

Temperature settings 
cannot be changed.

• The System switch is off.
• You are setting the temperatures outside 

their allowable ranges:

• Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
• Cool: 50 °F to 99 °F (10 °C to 37 °C).

Cool On is flashing. • The compressor protection delay has been 

activated. Cooling will not be activated until 
the delay ends (maximum of five minutes).

HI appears on the 
screen.

• The ambient (measured) temperature is 

above 122 °F (50 °C).

LO appears on the 
screen.

• The ambient (measured) temperature is 

below 32 °F (0 °C).

E1 appears on the 
screen.

• The temperature sensor circuit is opened. 

Replace the thermostat.

E2 appears on the 
screen.

• The temperature sensor circuit is shorted. 

Replace the thermostat.

RTH111

User Guide

Non-programmable Thermostat

400-631-001-A (RTH111 User 69-2061EFS).book  Page 1  Tuesday, June 5, 2007  2:24 PM

69-2061EFS-01

0.494822s