Hunter 44132 User's Manual

Hunter Thermostats User's Manual - 44132.
Download
Page  of 2
4.9, 1148 votes
background image

     ©2010 Hunter Fan Company 

44066-01   R20100524

This  thermostat  is  compatible  with  most  conventional  oil,  gas, 

electric,  hot  water  systems,  single  stage,  and  multi-stage  heat 

pumps. This thermostat will not control line voltage systems. 

You will need the following tools to complete your installation:
• Phillips Screwdriver (#2)
• Two 1.5V (AA) size alkaline batteries

Take  note  of  these  warnings  and  cautions  before 

proceeding:
• Read  all  installation  instructions  before  beginning  installation! 

If  you  still  need  assistance  after  reading  this  manual,  call  our 

Technical Support at 1-888-830-1326.

• Do  not  disconnect  the  wires  from  your  old 

thermostat  until  all  wires  have  been  properly 

labeled. You must label all wires properly because 

wire color may not indicate the function of the wire.

• All  wiring  must  be  done  in  accordance  with  local  code  and 

ordinances.

• Always turn power off to your furnace/compressor before the 

installation process. Failure to do so could result in damage to 

your thermostat and/or your heating and cooling system. Do not 

restore power until your installation is complete.

• This thermostat is designed for use with 24V AC/millivolt systems 

with a maximum of 1 amp. Higher amp or line voltage systems 

will cause damage to your system and increase the risk of fire.

44127, 44132 Programmable Thermostat

1

Preparation

Gathering Tools and Warnings

1

Old Thermostat Removal

1.  Turn off power to your compressor and furnace.

2.  Remove the cover to your existing thermostat. Some thermostats 

may  have  screws  or  other  locking  devices  that  must  first  be 

removed.  Once  the  wallplate  is  exposed,  locate  the  wire 

terminals and try to identify the wire designations. If the wire 

terminals are not visible, they may be connected to the back of 

the wallplate. Look for any additional screws, tabs, or locking 

devices to remove the wallplate. See Figure 1. If you are still 

unable to find the terminals for the wires, it may be necessary 

to contact the manufacturer of the original thermostat.

Installation

2

Mounting the Wallplate

Wire Color

Wire letter

Figure 2.

Figure 3b.

R, V

R

Y, Y1, M

Y

G, F

G

L, F, X

L

O, R

O

B

B

W2, E, X, 

Aux

E

Y2

Y2

C, X, X1, B

C

Heat Pump

W

G

Y

RH

C

Figure 6.

1.  Remove the mounting plate by pulling it straight off the back of 

the Thermostat. Figure 5. 

Figure 5.

2.  Pull the wires through the back of the mounting plate, ensuring 

none of the wire labels are removed. Figure 6.

Figure 7.

bubble level

Figure 8.

W

G

Y

RH

C

3.  Using a Phillips Screwdriver, Partially install 1 screw into the 

top hole of the thermostat. Ensure the thermostat is level using 

the bubble level on the mounting plate Figure 7., then install 

the other screw. Tighten both screws until secure. Figure 8.

Figure 11.

4.  Check the charts on the back of this sheet and identify your 

system type. They are divided by Conventional and Heat Pump 

installations.

5.  Raise all of the levers on the terminals you will be using. Heat 

Pump Installation labels are located on the left of the terminal 

blocks  on  the  mounting  plate  and  Conventional  labels  are 

on the right. If your installation does not call for the jumper, 

remove it  now. It is located underneath the wire holes, between 

the  RH and RC terminals on the conventional side. Figure 9.

6.   If one of the terminals you need has a tab in front of it, use 

your finger to break the tab away. Figure 9.

Note:  Only  break  tabs  you  know  you  will  be  using.  Double 

check your wiring configuration and make sure you are familiar 

with the terminals you will be using.

7.  Insert the bare end of each wire all the way into the appropriate 

hole  in  the  terminal  block  that  matches  the  wire  label  then 

lower the lever. This will lock each of the wires in place. Tuck 

excess wire back into wall after they have been locked in the 

mounting plate.

Note:  Do not insert the wires into the holes in the top of the 

mounting block. The wires should be inserted into the front close 

to the hole in the mounting plate. See Figure 8.

8.  Before mounting the thermostat onto the mounting plate, turn it 

over and find the 2 switches located on the circuit board next 

to the battery compartment.

9.  Set  the  system  switch  to  “Conv”  if  you  have  a  conventional 

HVAC system or “HP” if you have a heat pump system. Set the 

furnace type to “Elc” if you have an electric convention system 

or a heat pump. “Gas/Oil” will be used if you have gas or oil 

based conventional system. Figure 10.

Note:  Conventional  systems  use  the  compressor  for  air 

conditioning and a separate furnace for heat. Heat pump systems 

use the compressor for both heating and cooling.

10.  Lay the ribbon across the battery compartment and install 2 

(AA) Batteries into the back of the thermostat over it, Figure 

10., and snap the thermostat on to the mounting plate. Refer to  

“Setup” on page 10 of your owner’s manual to continue setup, 

scheduling, and daily use.

If you have any additional questions or problems with your Hunter 

thermostat, please call:

USA: 1-888-830-1326

Canada: 1-866-268-1936

Hours of operation are from 7:00 am to 7:00 pm Monday - Friday 

and 8:00 am to 5:00 pm on Saturday, Central Time. You may also 

contact us over the Internet at www.hunterfan.com.

Technical Support

Installation Sheet

Conventional

RH

RH

RC, R

RC

Y, Y1

Y

G, F

G

W, W1

W

W2

W2

Y2

Y2

C

C

A

A

Figure 3a.

Figure 1.

Y

RC

G W

Y

RC

G W

Thermostat

Cover

Wallplate

Thermostat

Cover

Wallplate

W

G

Y

C

A          C          

Y2       

W2 

 

 

     

W         G          

  

  

RC

  

  

RH

RH

Tabs

Levers

Figure 9.

Jumper

Insert 

Wires

Co

nv

                HP

El

ec

  

 G

as

Figure 10.

Gas

Oil

Elc

H.P.

Cnv.

Labeling Your Wires

Use  the  table  in  Figure  2.  to  write  down  your  wire  colors  and 

the letter designations on the old thermostat. This will allow you 

to  keep  a  record  of  your  old  thermostat’s  wiring  configuration 

should you need to refer to it at a later time. This will also help our 

Technical  Support  Department  determine  your  system  type  and 

proper wiring, should you need to contact them. Wire color does 

not indicate the function of the wire, this is being used only to help 

determine which wire has what letter designation.

After  writing  down  the  wire  colors 

and  letters,  use  the  terminal  stickers 

to label the wires. Figures 3a and 3b 

will  help  you  depending  on  system 

type;  Conventional  or  Heat  Pump. 

Not all terminals will be used, this will 

be determined by your system type.

To ensure wires do not fall back into 

the  wall  hole,  you  may  tape  them 

to  the  wall,  or  wrap  them  around  a 

pencil.

Figure 4. may assist you if your old 

thermostat is a heat pump from one 

of the listed Manufacturers and your 

wire labels do not match. It is located 

on  the  back  of  this  sheet.  These  tips 

will also help you in wiring:

• Only  1  reversing  valve  is  needed 

to  run  a  heat  pump.  If  both  “O” 

and “B” are present, “B” may be a 

common wire. 

• Often, 2-wire heat only systems do 

not have terminal labels. Connect 1 

wire to the Rh terminal and the other 

to W.

• If  you  have  a  3-wire  hot  water 

system,  the  damper  valve  control 

wire will be labeled and attached to 

the “A” terminal.

• If  you  need  further  assistance 

with  wiring,  or  determining  your 

system  type,  you  can  contact  our 

Technical  Support  Department.  See 

the  “Technical  Support”  section  for 

information.

0.595656s