Maytag UXT5230BDS Dimension Guide

Maytag Hoods Dimension Guide - UXT5230BDS.
Download
Page  of 2
4.5, 2339 votes
background image

29

⁷⁄₈" (75.9 cm) – 30" (76.2 cm) model

35

⁷⁄₈" (91.1 cm) – 36" (91.4 cm) model

7

¹⁄₂" 

(19.1 cm)

2" 

(5.1 cm)

1

¹⁄₂" 

(3.8 cm)

1" 

(2.5 cm)

1

¹⁄₂" 

(3.8 cm)

6" 

(15.2 cm)

9" 

(22.9 cm)

12" 

(30.5 cm)

³⁄₄" 

(1.9 cm)

³⁄₈" 

(9.5 mm)

17

¹⁄₂" 

(44.5 cm)

PRODUCT MODEL NUMBERS

VENTING REQUIREMENTS

UXT5230BD

UXT5236BD

Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply.
Use copper wire only. A time-delay fuse or circuit breaker and
separate circuit is recommended.

Range Hood – 30" (76.2 cm) and 36" (91.4 cm)

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10646405

12/14

CABINET OPENING DIMENSIONS

Roof Venting

 

Wall Venting

A. 6" (15.2 cm) round vent or a 

(8.3 x 25.4 cm) vent through roof 

B. Round vent: use 6" (15.2 cm) round  

damper (purchased separately)

C. 18" (45.7 cm) to 24" (61.0 cm) 

above cooking surface

D. Roof cap

B. 3

¹⁄₄" x 10" (8.3 x 25.4 cm) vent 

through the wall

C. 18" (45.7 cm) to 24" (61.0 cm)  

above cooking surface

D. Wall cap

A

B

D

C

A

B

C

D

3

¹⁄₄" x 10"

A. 6" (15.2 cm) round vent or a 

(8.3 x 25.4 cm) vent through wall

3

¹⁄₄"

OVERALL DIMENSIONS

36" (91.4 cm)
base cabinet
height

24" (61.0 cm ) min.

30" (76.2 cm)

suggested max.

bottom of hood to

cooking surface

13" (33 cm)

cabinet depth

18" (45.7 cm) min.

24" (61 cm)

suggested max.

bottom of cabinet

to cooking

surface

30" (76.2 cm) or

36" (91.4 cm)

min. cabinet 

opening width

3

¹⁄₄" x 10" (8.3 x 25.4 cm) vent system

3

¹⁄₄" x 10" (8.3 x 25.4 cm) vent system

Maximum length

=  35 ft.

(10.7 m)

1 - 90° elbow

=   5 ft.

(1.5 m)

8 ft. (2.4 m) straight

=   8 ft.

(2.4 m)

1 - wall cap

=   0 ft.

(0 m)

Length of 3

¹⁄₄" x 

10" (8.3 x 25.4 cm) system

= 13 ft.

(3.9 m)

Note: Flexible vent is not recommended

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm)
90° elbow = 
5 ft. (1.5 m)

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm)
flat elbow = 
12 ft. (3.7 m)

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm)
wall cap = 

0 ft. (0 m)

2 ft.
(0.6 m)

6 ft. ( 1.8 m)

wall cap

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm)
elbow

Maximum length

= 35 ft.

(10.7 m)

1 - 90° elbows

= 5 ft.

(1.5 m)

8 ft. (2.4 m) straight

= 8 ft.

(2.4 m)

1 - wall cap

= 0 ft.

(0 m)

Length of 7" 
(17.8 cm) system

= 13 ft.

(3.9 m)

Note: Flexible vent is not recommended

6" (15.2 cm) vent system

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm) to
6" (15.2 cm) = 
4.5 ft. (1.4 m)

90° elbow =
5 ft. (1.5 m)

45° elbow =
2.5 ft. (0.8 m)

3

¹⁄₄" x 10" 

(8.3 x 25.4 cm) 
to 6" (15.2 cm) 
90° elbow = 
5 ft. (1.5 m)

6" (15.2 cm)
wall cap = 
0 ft. (0 m)

elbow

wall
cap

6 ft. (1.8 m)

2 ft.

(0.6 m)

6" (15.2 cm) vent system

0.549253s