Condensation Sensor Plus – Fan Only
• Combination humidity and temperature sensor anticipates dew point, automatically turning the fan on.
• Adjustable Minutes Per Hour fan timer (0-60 mins) for compliance with ASHRAE 62.2.
• Moisture Sensitivity Selector allows fine tuning for dry or moist environments. 
• Automatic Fan Control - 30 minute countdown timer initiates after moisture returns to normal levels.
• Manual Fan Control - 20 minute countdown timer initiates once fan is turned on.
• Blue LED indicates when the fan is on.
• Commercial Grade - 8 Amp max load, 2 year
   limited warranty

*.

• For indoor use. Includes matching wall plate. 
• May be used to comply with ASHRAE 62.2, 
   LEED, ENERGY STAR® 3.0 and CALGreen.

FV-WCCS1-W (White)
FV-WCCS1-A (Light Almond)

FV-WCCS2-W (White)
FV-WCCS2-A (Light Almond)

Product Specifications 

Ground 

Grounding

Feature

Blue LED When On

Amperage

15

Maximum Fan Load

8 Amps

Voltage

120 Volts 

Dry Contact Switching

24 Volt AC  Input/Output 

Terminations

6" Leads

Connections (Copper Wire Connections)

Use #14 or #12

Max Fluorescent Light Load

N/A

Standards and Classifications

UL/CSA Listed

Warranty

2 Year Limited 

Specification Submittal Data

WhisperControl

Panasonic Eco Solutions North America

Eco Products Divsion

Two Riverfront Plaza 

Newark, NJ 07102
us.panasonic.com/ventfans

Condensation Sensor Plus – Fan/Light
• Combination humidity and temperature sensor anticipates dew point, automatically turning the fan on.
• Adjustable Minutes Per Hour fan timer (0-60 mins) for compliance with ASHRAE 62.2.
• Moisture Sensitivity Selector allows fine tuning for dry or moist environments.
• Automatic Fan Control - 30 minute countdown timer initiates after moisture returns to normal levels.
• Manual On/Off Fan Control - 20 minute countdown timer initiates once fan is turned on.
• Manual On/Off Light control.
• Blue LED indicates when the fan is on.
• Commercial Grade - 8 Amp max load, 2 year 
   limited warranty

*.

• For indoor use. Includes matching wall plate.
• May be used to comply with ASHRAE 62.2, 
   LEED, ENERGY STAR® 3.0 and CALGreen.

Product Specifications 

Ground 

Grounding

Feature

Blue LED When On

Amperage

15

Maximum Fan Load

8 Amps

Voltage

120 Volts 

Dry Contact Switching

24 Volt AC  Input/Output 

Terminations

6" Leads

Connections (Copper Wire Connections)

Use #14 or #12

Max Fluorescent Light Load

400 Watt

Standards and Classifications

UL/CSA Listed

Warranty

2 Year Limited 

* One year additional fan warranty available when a Panasonic WhisperCeiling/Lite, WhisperValue 

or WhisperFit/Lite fan is controlled by the Panasonic Condensation Sensor Plus.

For complete Installation Instructions visit 
us.panasonic.com/ventfans 

* One year additional fan warranty available when a Panasonic WhisperCeiling/Lite, WhisperValue 

or WhisperFit/Lite fan is controlled by the Panasonic Condensation Sensor Plus.

On/Off 
FV-WCCS1-W (White)
FV-WCCS1-A (Light Almond)

Timer and Sensor Settings: 
Minutes Per Hour (MPH) fan 
timer (left) and Moisture 
Sensitivity Selector (right), 
hidden behind a removable 
cover.
Minutes Per Hour (MPH) Fan Timer:
Runs fan for a selected amount of time every hour, (0-60 mins.) for 
compliance with ASHRAE 62.2. For example, set to "0", the MPH timer 
will never turn on. Set to "10", the MPH timer will turn the fan on 10 
minutes every hour. Set to "60", the MPH timer will run the fan all the 
time. The MPH fan timer will also credit any manual use time to the next 
hours operation (up to 3 hours ahead).  

Moisture Sensitivity Selector: Adjusts the unit's sensitivity based 
on regional climate, size of bathroom and preferred dryness level. 
Choose from High, Average or Low sensitivity. 
Fan ON/OFF: Turns 20-minute countdown timer ON and OFF (can 
be used to temporarily override the Condensation Sensor Plus).

High Sensitivity - Most sensitive setting, for dryer climates 
and/or larger rooms.

Average Sensitivity Sensitivity - Condensation Sensor 
Plus comes factory set to this most common setting.
Low Sensitivity - Least sensitive setting, used in hotter 
and more humid climates.

Timer and Sensor Settings: 
Minutes Per Hour (MPH) fan 
timer (left) and Moisture 
Sensitivity Selector (right), 
hidden behind a removable 
cover.
Minutes Per Hour (MPH) Fan Timer:
Runs fan for a selected amount of time every hour, (0-60 mins.) for 
compliance with ASHRAE 62.2. For example, set to "0", the MPH timer 
will never turn on. Set to "10", the MPH timer will turn the fan on 10 
minutes every hour. Set to "60", the MPH timer will run the fan all the 
time. The MPH fan timer will also credit any manual use time to the next 
hours operation (up to 3 hours ahead).  

Moisture Sensitivity Selector: Adjusts the unit's sensitivity based 
on regional climate, size of bathroom and preferred dryness level. 
Choose from High, Average or Low sensitivity. 
Fan ON/OFF: Turns 20-minute countdown timer ON and OFF (can 
be used to temporarily override the Condensation Sensor Plus).

On/Off 
FV-WCCS2-W (White)
FV-WCCS2-A (Light Almond)

High Sensitivity - Most sensitive setting, for dryer climates 
and/or larger rooms.

Average Sensitivity Sensitivity - Condensation Sensor 
Plus comes factory set to this most common setting.
Low Sensitivity - Least sensitive setting, used in hotter 
and more humid climates.