ReliOn Digital Temple Thermometer Instruction Manual

ReliOn Thermometer Instruction Manual - Digital Temple Thermometer.
Download
Page  of 4
4.2, 1067 votes
background image

Thank you for purchasing the ReliOn® Digital Temple
Thermometer. The thermometer enables accurate

measu

temperature

rements in approximately 6-10 seconds,

using simple steps.
Table of Contents:
QUICK START
Section 1    About Body Temperature Measurement
Section 2    Instal ing and Replacing the Batteries
Section 3    Guidelines for Use
Section 4    Care and Cleaning
Section 5    Troubleshooting and Special Indications
Section 6    Technical Information
Section 7    Warranty and Service Information
IMPORTANT!  Read user manual before using the thermometer.
QUICK START
1. Instal batteries into the thermometer. Make sure the polarity is correct

(see section 2).

2. Press and release the blue ON/OFF button.  Unit wil beep once.  Wait until it

beeps again twice and °F appears in the display (see section 3).

3. Place and hold the thermometer probe firmly to the skin at the temple and

wait several seconds for the device to beep once more (see section 3).

4. Read the temperature on the display (see section 3).
General Warnings:
1. Measurement body location is the temple, in proximity to the temporal artery,

between the eye socket and the hairline.

2. Do not place the thermometer on scarred tissue compromised by skin disorder,

open sores or abrasions and patients in trauma.

3. Consult your physician when using drug therapies that may raise the local skin

temperature in the forehead; this may lead to incorrect reading.

4. Do not place the thermometer on skin exposed to direct sunlight, fireplace heat,

air conditioner flow and cold/warm compress therapies.

5. Keep the thermometer out of reach of unsupervised children.
6. Do not drop the thermometer or expose to heavy shock.  The unit is not

shock proof.

Instruction for Use

            Digital Temple Thermometer

7. Do not immerse the thermometer in water or any other liquid.  The unit is not

water proof.

8. In order to ensure accurate measurement, please wait at least two minutes

between consecutive measurements for the unit to readjust to room temperature.

9. The device is not suitable for use in presence of flammable anesthetic mixture

with air or with Oxygen or Nitrous Oxide.

10. Do not store the unit in direct sunlight, at a high temperature, in high humidity

or dust.  Performance of the unit may be degraded.

11. Stop using the thermometer if it operates erratical y or if display malfunctions.
12. Clean the thermometer probe before storing. (See section 4, Care & Cleaning)
13. Do not attempt to disassemble the unit except to replace the batteries.
14. If the thermometer has been stored at below-freezing temperatures, al ow the

unit to warm natural y to room temperature before using.

15. Performance of the device may be degraded if operated or stored outside stated

temperatures and humidity ranges or if the patient's temperature is below the
ambient (room) temperature.

1. About Body Temperature Measurement:
How does the thermometer work?
Your ReliOn® Digital Temple Thermometer accurately measures body heat using 
Rapid, Accurate, State of the Art Technology. Sensor      rapidly tracks the heat flow
generated from blood vessels       to the skins surface

     and converts measurement to body temperature.

Information about Body Temperature
What is  "normal" body temperature?
"Normal" body temperature varies from person to person and changes 
according to time of day and body location. Hot or cold baths, physical exercise,
smoking and drinking, hot or cold drinks may change body temperature by one 
degree or more.
The following table shows the Temperature ranges:

What is fever?

Average normal temperature ranges

Forehead

Over 100.0°F / 37.8°C

97.0°F - 100.0°F  /  36.1°C – 37.8°C

Rectal*

Over 100.4°F / 38°C

97.3°F - 100.4°F  /  36.3°C – 38°C

Oral (mouth)*

Over 100.0°F / 37.8°C

97.0°F - 100.0°F  /  36.1°C – 37.8°C

Axil a (armpit)*

Over 99.0°F / 37.2°C

95.4°F - 99.0°F  /  35.2°C – 37.2°C

* Fever definitions according to the American Medical Association

The thermometer is designed to measure with precision the temperature in the forehead,
in proximity to the temporal artery, between the eye socket and the hairline. It is
important to know that the thermal characteristics of each measurement body location –
temporal, axil ary, oral or rectal - are unique. The variance in temperature measurement in
different body locations is due to the human body and not the thermometer. 
The thermometer readings are equivalent to oral measurements.    
IMPORTANT:
" It is recommended that you measure the body temperature of each

individual when healthy to establish a  "normal" temperature.

" Due to the unique body physiology of each person, it is recommended

that you take a persons temperature at the same temple location in
comparative measurements.

2. Installing and Replacing the Batteries:
The thermometer uses 2 standard  AAA 1.5v batteries. To instal /replace :
1. Remove the battery cover by sliding it out of its housing.
2. Firmly attach the batteries to their place, make sure polarity is correct.
3. Slide the battery cover back into place.
IMPORTANT: It is recommended to remove the batteries from the thermometer
when it is not used for a long period.
WARNING: Do not dispose of batteries in fire, recharge, put in backwards, disassemble,
mix with used or other battery types – they may explode or leak and cause injury. Waste
batteries should be deposited in batteries recycling trash only.
3. Guidelines for Use:
a. 
Use this thermometer on clean dry skin. Wipe away any perspiration prior to use.
b. Make sure that the thermometer and the patient do not move while

measurement is in progress.

c. Correct placing and good contact with the body ensure reliable readouts.
d. Do not try to take a measurement until the two beeps are heard.
Setting the Operating Scale °F or °C
The device setting is by default Fahrenheit (°F), however at any time, the scale may be
changed. To change the scale to Celsius (°C), or back to °F, by pressing the Power button
within the first 3 seconds of turning on the unit.

Operating the Thermometer
1. Press and release the blue Power

              button. You wil  hear one
beep.  Al  segments wil  be displayed.

2. The result of the last temperature

measurement wil  be displayed for 2 seconds*.

3. Wait for the hourglass icon to disappear,

then two beeps wil  be heard to indicate that
the thermometer is now "ready to measure".

4. Take a measurement according to the

fol owing guidelines:

Taking Temperature:
a. Make sure temporal area is dry and clean.
b. Remove hair from the temporal area.
c. Place the thermometer probe in the center of the temporal area

between the eye socket and the hairline.  Gently press it against
the temple to ensure good contact with the skin is maintained.

d. Hold the device stil  and keep the patient stil for the duration of

the measurement.

e. As soon as the thermometer is in place, the measurement starts

automatical y.  A running circle wil  appear indicating that
measurement is progressing successful y.

f. A temperature reading wil  be displayed within 6 – 10 seconds. One

long beep wil  be heard to indicate that measurement is complete.

g. Wait for the hourglass icon to disappear, then two beeps wil  be

heard to indicate that the thermometer is now
"ready for measurement again".

h. Press and release the blue Power             button to turn

the thermometer off.

i. If you want to get the maximum accuracy,please wait two minutes

after turning the thermometer off and then begin again at Step 1 of
"Operating the Thermometer".

(1) One "Beep"

(g) Two "Beeps"

(h)

(f) One long "Beep"

(2)

(4) Two "Beeps"

(3)

1

2

3

4

 

0.575706s