Sanyo 09KLS71 User's Manual

Sanyo Air Conditioners User's Manual - 09KLS71.
Download
Page  of 2
4.7, 1705 votes
background image

System: 09KLS71  Indoor/Outdoor: KS0971/CL0971

Wall Mounted Low Ambient Air Conditioner

Power   

 

V/PH/Hz  

 

115/1/60

Circuit Ampacity
Fuse Size, Max.

Compressor
No. used
R.L. Amps  - L.R.
Crankcase Heater

Outdoor Unit
Fan type  
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size

Indoor Unit
Fan type  
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size

Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max
Lift Difference, Max
Line Size
Line Size

Dimensions
Indoor Unit

Outdoor Unit

Weight
Net 
Shipping

Shipping Volume

Performance Data @ ARI Standard Conditions (115V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating

                  (A)                                               20

                    (A)                                               20

        General Data (at 115V)

1

                           (A)                                             7.6 - 20

                     (W)                                                    20

  Propel er

15-3/4-1

DC Motor

                  (RPM)                                         8 - 750

             (W)                                              50 - 1

16

                           (Pints/H)                                      3.4

(BTU/H)        9,000 (3,000-9,000)

(BTU/H)                                7,650

(BTU/H)                                  1,350

(Uncrated)        11-7/32 x 32-15/32 x 7-7/16

             (W)                             755 (250-755)

Aluminum Fin & Copper Pipe

Corrugated Plate - Inner Riffeled

       (in.)                                               5/16”

2.09

Split System Submittal Data

Electric Expansion Valve

Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:

Approval:
Date:
Construction:
Unit #:
Drawing #:

2 - 18.1

            (sq.ft.)                                                3.1

(lbs.)         19.8                                           72.8

                          (A)                                 7.6 (2.5-7.6)

(in. O.D. Discharge)                       1/4”

(in. O.D. Suction)                         3/8”

DC Rotary Inverter

                  (High)                                               883

                  (A)                                                   0.6

R410A

(in.)                                        H x W x D

(Crated)         13-25/32 x 35-7/16 x 10-1/32

Indoor                                   Outdoor

(cu.ft.)        2.82                                           6.36

Indoor                                   Outdoor

(lbs.)         24.3                                           79.4

             (dB-A)                                              46

Cross Flow

3-11/16  24-31/32 - 1

3 & Auto

                  (RPM, High)                                 4 - 1200

             (W)                                                16 - 1

Aluminum Plate Fin & Copper Tube

Slit Plate - Inner Riffeled

       (in.)                                                9/32”

2 - 19.5

            (sq.ft.)                                                2.02

(HI/Med/Lo)                          282/247/200

                  (A)                                                   0.45

  (in.)                                              23/32”

             (Hi) (dB-A)                                                34

Flare

50
23

(Uncrated)      21-9/16 x 28-11/32 x 10-7/16

(Crated)             23-5/8 x 33-11/16 x 14-1/4